START-UP
  • Check level of materials in containers, making sure level is always over 1/3
  • Clean off the dispense manifold with plastic mixer nozzle removed. Pump material into waste container to verify smooth, air-free flow of both materials. Wipe head clean and coat the dispense manifold with compatible lubricant.
  • Place new plastic mixer nozzle on applicator block and secure with mixer retainer nut.

SHUT-DOWN
  • Turn off motor controller and disconnect the plug from power.
  • Remove plastic mixer nozzle and discard.
  • Clean head of applicator and coat the threads and tip with compatible lubricant.
  • Lubricate grease zerks on applicator head. Fill until the lubricant comes out of the ports (holes) where the mixer is attached. Wipe away any displaced material.
  • Lubricate grease zerks on the side of each pump. The chamber being filled is between the shaft seals.
  • Lubricate the pump's internal gears:
    • Open the end of the bleed valve on the bottom of each pump.
    • Fill the zerk on top of the pump until fresh lubricant comes out the hole in the side of the bleed valve.
    • Close the bleed valve.
  • Verify that tanks are over 1/3 full.