TROUBLESHOOTINGGMP-075

As soon as a problem is noticed, immediately remove the disposable plastic mixer nozzle and try dispensing material. This may prevent or purge material cross-over if it has not already hardened. After the static mixer is removed, THEN check the following:

  1. Is the static mixer nozzle plugged? (material set up)
  2. Is there sufficient air or electrical supply?
  3. Is the drive belt functioning properly?
  4. Is there sufficient material?

Do a ratio check at the dispense valve:

  1. Check to see if there is flow from both pumps.
  2. Check to see if the check valves are cutting off material evenly when the trigger switch is de-activated.
  3. Check phasing. Is one material flowing before the other?
  4. Measure the volume output of each material.

If ratio check is not correct, the problem is in the meter.

  1. Supply blockage or low material. (viscosity too high)
  2. Belt or pump worn.
  3. Air entrapped in pumps or hoses

Click Here for Printable Troubleshooting Guide